The two code paths in Washington
Washington's residential code sets its own crawl space rules in WAC 51-51-0408, and an encapsulation has to follow one of two routes.
Sealed, with no vents. The state rule lists two numbered items. Item 1: a continuous Class I vapor retarder on the soil, lapped 6 inches, sealed or taped, and taken 6 inches up the stem walls, together with a radon system to Appendix AF. Item 2: continuous mechanical exhaust outside at 1 cfm per 50 square feet. Washington offers no dehumidifier option in place of the exhaust, and the City's building official confirms how the two items apply to your address.
Vented, with reduced vents. Under the same section, with a Class I vapor retarder on the soil, the vent area can drop from 1 square foot per 300 square feet of floor to 1 per 1,500, provided cross ventilation remains. Under-venting below the 1-per-300 ratio, or installing operable louvers, triggers a radon vent requirement.
So blocking vents and plugging in a dehumidifier is not an encapsulation here. A good plan names the path.